Original Mindray Battery 11.1V 4600mAh Li-ion for ECG-1200/1250 and PM-7000/8000 Series

1
MOQ
USD
قیمت
Original Mindray Battery 11.1V 4600mAh Li-ion for ECG-1200/1250 and PM-7000/8000 Series
امکانات گالری توضیحات محصول درخواست نقل قول
امکانات
مشخصات
نام محصول:: باتری ميندری
مدل:: 0146-00-0099
نوع سلول:: لیتیوم یون
وضعیت:: اصل
ولتاژ:: 11.1 ولت
ظرفیت:: 4.6ah
انرژی:: 51.56 وات ساعت
زندگی چرخه:: قابل شارژ
ارسال توسط:: DHL و FedEx
رنگ:: مشکی
اندازه:: 160×75×35 میلی متر
برجسته کردن:

11.1V Mindray Battery,4600mAh Medical Equipment Battery,ECG-1200/1250 Rechargeable Medical Battery

,

4600mAh Medical Equipment Battery

,

ECG-1200/1250 Rechargeable Medical Battery

اطلاعات اولیه
پرداخت
جزئیات بسته بندی: بسته کارتن
شرایط پرداخت: T/T، وسترن یونیون، پی پال
توضیحات محصول
Mindray Battery 11.1V 4600mAh REF 0146-00-0099
This genuine Mindray battery is primarily compatible with Mindray portable electrocardiographs (ECG-1200/ECG-1250 series) and patient monitors (PM-7000/PM-8000 series). As a Ni-MH rechargeable battery with approximately 600-800 cycle life, it offers high energy density and 4.6Ah capacity, providing at least 8 hours of continuous operation in low-power mode. The ideal power solution for portable medical devices.
Compatible Devices
  • Portable Electrocardiographs: ECG-1200/1250 Series - Compact, feature-rich devices with built-in printing system, ideal for primary healthcare facilities and home visits.
  • Basic Vital Signs Monitor: PM-7000/8000/9000 Series - Detects multiple parameters with low power consumption, suitable for inpatient wards and outpatient clinics.
  • Small Portable Ultrasound: M5/M7 Series (Entry-level) - Simplified functions with half-day battery life, perfect for emergency rooms and rural clinics.
Technical Specifications
Product name Mindray battery
REF 0146-00-0099
Type Li-ion
Voltage 11.1V
Capacity 4600mAh
Energy 51.06Wh
Charge time 4-6 hours
Cycle life ≥500 times
Color Black
Size 160×75×35mm
Weight About 450g
Original Mindray Battery 11.1V 4600mAh Li-ion for ECG-1200/1250 and PM-7000/8000 Series 0 Original Mindray Battery 11.1V 4600mAh Li-ion for ECG-1200/1250 and PM-7000/8000 Series 1
Frequently Asked Questions
Q1: After charging, the battery only has 80% charge and cannot be fully charged. Is this a battery malfunction?
A1: This is not a battery malfunction. The issue may be caused by insufficient charger power. We recommend using the original charger for optimal performance.
Q2: The battery casing has a slight bulge, is elastic when pressed, and has no leakage. What could be causing this?
A2: This indicates overcharging/over-discharging has caused internal gas production, representing a potential safety hazard. Immediately discontinue use, keep away from heat sources, and contact battery recycling for replacement.
Q3: After installing the battery, the device occasionally loses power when moved. What could be the reason?
A3: This may be caused by worn battery slot clips or slight battery casing deformation. Inspect the battery clips and replace if necessary. If clips appear normal, apply thin adhesive foam to the battery side to improve fit.