15VDC 7.2Ah AED Battery with 5-year Standby for Long-term Emergency Backup and High-power Defibrillation

1
MOQ
USD
قیمت
15VDC 7.2Ah AED Battery with 5-year Standby for Long-term Emergency Backup and High-power Defibrillation
امکانات گالری توضیحات محصول درخواست نقل قول
امکانات
مشخصات
نام محصول:: باتری های یکبار مصرف
PN:: CR1734
نوع سلول:: باتری Li-MnO2
وضعیت:: اصل
ولتاژ:: 15 ولت
ظرفیت:: 7.2Ah
انرژی:: 108 وات ساعت
زندگی چرخه:: یکبار مصرف
ارسال توسط:: DHL و FedEx
رنگ:: مشکی
اندازه:: 5 سال باز نشده
برجسته کردن:

15VDC AED Battery,7.2Ah Defibrillator Battery,5-year Standby Medical Battery

,

7.2Ah Defibrillator Battery

,

5-year Standby Medical Battery

اطلاعات اولیه
پرداخت
جزئیات بسته بندی: بسته کارتن
شرایط پرداخت: T/T، وسترن یونیون، پی پال
توضیحات محصول
Metrax Primedic HeartSave M250 Lithium Metal Battery UN3090 95394 15VDC 7.2Ah
This specialized battery is designed for the Metrax Primedic M250 AED (Model 95394). With core specifications of 15VDC/7.2Ah, it offers high capacity for long-term emergency backup and instantaneous high-power defibrillation in medical applications. The disposable Li-MnO₂ battery requires no daily charging or maintenance and can remain in standby mode within the M250 AED for 5 years when unopened, supporting monthly automatic self-checks.
Core Application Scenarios
  • Public Spaces: Ideal for long-term AED standby in shopping malls, schools, stadiums, and subway stations; 5-year standby life minimizes maintenance requirements.
  • Medical Settings: Suitable for ambulances, primary healthcare facilities, and community health centers; supports pre-hospital emergency care and cardiac arrest cases.
  • Special Environments: Effective for outdoor work sites in high-altitude and cold regions (oil fields, mining areas); wide temperature range ensures reliable operation.
Technical Specifications
Product Name AED Battery
Model 95394
Cell Type Li-MnO₂
Voltage 15V
Capacity 7.2Ah
Energy 108Wh
Cycle Time Disposable battery
Number of Defibrillations 200+ times
Color Black
MOQ 1PC
Shelf Life 5 years unopened
Frequently Asked Questions
Q1: After inserting the electrode pads during emergency treatment, the AED displays "Battery Error" and fails to discharge for defibrillation. What could be causing this?
A1: This may indicate a faulty or loose battery clip or oxidized battery terminals. Verify the clip is securely fastened and reinstall it. If the clip is damaged, contact a technician for replacement. Alternatively, clean oxidized terminals with a dry cotton cloth and reinstall.
Q2: An AED has been in long-term use at a local health center (unused for 1 year). Monthly self-tests are normal, but white powder (not an oxide layer) appears at the battery terminals. What could be the cause?
A2: This likely results from excessive humidity in the battery compartment, causing lithium salt deposits. Thoroughly clean the powder and place medical-grade desiccant in the compartment. During monthly self-tests, check for recurrence and replace desiccant as needed.
Q3: The battery is unopened but stored for more than one month past its expiration date. It appears normal. Can it be used temporarily?
A3: Expired lithium metal batteries experience electrolyte decomposition. While voltage may appear normal, instantaneous discharge capacity decreases by 30%-50%, potentially compromising defibrillation energy. Immediate replacement is strongly recommended.